10 Inspection, Maintenance, and Troubleshooting

10.1.3 Warning Displays

10-6

10.1.3 Warning Displays

Warning display, names, and meanings are shown in table 10.2.

Note: 1. The following warnings are not detected when Pn008 = n. 1

(Does not Detect a Warning).

A.900, A.901, A.910, A.911, A.920, A.930, A.941

2. A.94 , A.95 , and A.96 warnings are not detected depending on the warning check mask

(Pn800.1) settings.
A.94 and A.95 warnings are detected for default settings.

Table 10.2 Warning Displays and Outputs

Warning

Display

Warning Name

Meaning

A.900

Position Error Pulse Overflow

Position error pulse exceeded the parameter settings (Pn520

×Pn51E/100).

A.901

Position Error Pulse Overflow
at Servo ON

When the servo turns ON, the position error pulses exceeded the parameter
setting (Pn526

×Pn528/100).

A.910

Overload

This warning occurs before the overload alarms (A.710 or A.720) occur. If
the warning is ignored and operation continues, an overload alarm may
occur.

A.911

Vibration

Abnormal vibration at the motor speed was detected. The detection level is
the same as A.520. Set whether to output an alarm or warning by “Vibration
Detection Switch” of Pn310.

A.920

Regenerative Overload

This warning occurs before the regenerative overload alarm (A.320) occurs.
If the warning is ignored and operation continues, a regenerative overload
alarm may occur.

A.930

Absolute Encoder Battery
Voltage Lowered

This warning occurs when the absolute encoder battery voltage is lowered.
Continuing the operation in this status may cause an alarm.

A.941

Change of Parameters
Requires Setting Validation

The change of the parameters can be validated only after turning the power
ON from OFF.

A.94A

Data Setting Warning 1
(Parameter Number Error)

Incorrect command parameter number was set.

A.94B

Data Setting Warning 2
(Out of Range)

Command input data is out of range.

A.94C

Data Setting Warning 3
(Calculation Error)

Calculation error was detected.

A.94D

Data Setting Warning 4
(Parameter Size)

Data size does not match.

A.95A

Command Warning 1

Command was sent though command sending condition was not satisfied.

A.95B

Command Warning 2

Unsupported command was sent.

A.95C

Command Warning 3

Command condition is not satisfied for parameter settings.

A.95D

Command Warning 4

Command, especially latch command, interferes.

A.95E

Command Warning 5

Subcommand and main command interfere.

A.960

MECHATROLINK
Communications Warning

Communications error occurred during MECHATROLINK
communications.