7.4 Settings According to Host Controller

7-21

7.4.4 Motion Settings

Motion settings are performed using the following parameters.
Set them according to the machine system.

(1) Positioning Completed Width

Set the width for positioning completed (PSET) in STATUS. When output has been completed (DEN = 1) and the
position is within the positioning completed width of the target position (TPOS), PSET will be set to 1.

This parameter is used to set the COIN output signal width, but can also be used as the MECHATROLINK II PSET width
in STATUS. The COIN output signal width will also be changed.

(2) NEAR Signal Width

Set the width for positioning proximity (NEAR) in STATUS. Regardless of whether or not output has been
completed (DEN = 1), when the position is within the positioning proximity width of the target position, NEAR
will be set to 1.

This parameter is used to set NEAR output signal width, but can also be used as the MECHATROLINK II NEAR width in
STATUS. The NEAR output signal width will also be changed.

(3) Home Position Width

Set the home position detection (ZPOINT) width.

(4) Final Travel Distance for External Positioning

Set the distance to move after the external signal input position when external positioning is used. When the
direction is negative or the distance very short, a deceleration stop will be performed and the movement begins
again in the reverse direction.

Pn522

Positioning Completed Width

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 1073741824

1 reference unit

7

Immediately

Position

INFO

Pn524

NEAR Signal Width

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 1073741824

1 reference unit

7

Immediately

Position

INFO

Pn524

NEAR Signal width

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 250

1 reference unit

10

Immediately

Position

Pn814

Final Travel Distance for External Positioning

Setting Range

Setting Unit

Factory Setting

Setting Validation

-1073741823 to 1073741823

1 reference unit

100

Valid when DEN = 1

Position