3 write parameter (prm_wr: 02h), 4 read alarm or warning (alm_rd: 05h) – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 176

6.4 Subcommands
6-45
6.4.3 Write Parameter (PRM_WR: 02H)
6.4.4 Read Alarm or Warning (ALM_RD: 05H)
Byte
PRM_WR
Description
Command
Response
Processing
classifications
Data communica-
tions command
group
Processing time
Within 6 ms
17
02H
02H
• Writes the parameters. This command has the same function as the main
command PRM_WR.
• This command can be used only with the following main commands:
NOP, ID-RD, HOLD, LTMOD_ON/OFF, SMON, SV_ON/OFF,
INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL
18
Substatus
19
NO
NO
20
21
SIZE
SIZE
22
PARAMETER
PARAMETER
23
24
25
26
27
28
29
Byte
ALM_RD
Description
Command
Response
Processing
classifications
Data communica-
tions command
group
Processing time
6 ms to 2 s
17
05H
05H
• Reads the alarm or warning. This command has the same function as the main
command ALM_RD.
• This command can be used only with the following main commands:
NOP, ID-RD, HOLD, LTMOD_ON/OFF, SMON, SV_ON/OFF,
INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL
18
Substatus
19
ALM_RD_MOD ALM_RD_MOD
20
ALM_DATA
21
22
23
24
25
26
27
28
29