3 write parameter (prm_wr: 02h), 4 read alarm or warning (alm_rd: 05h) – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 176

Advertising
background image

6.4 Subcommands

6-45

6.4.3 Write Parameter (PRM_WR: 02H)

6.4.4 Read Alarm or Warning (ALM_RD: 05H)

Byte

PRM_WR

Description

Command

Response

Processing
classifications

Data communica-
tions command
group

Processing time

Within 6 ms

17

02H

02H

• Writes the parameters. This command has the same function as the main

command PRM_WR.

• This command can be used only with the following main commands:

NOP, ID-RD, HOLD, LTMOD_ON/OFF, SMON, SV_ON/OFF,
INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL

18

Substatus

19

NO

NO

20
21

SIZE

SIZE

22

PARAMETER

PARAMETER

23
24
25
26
27
28
29

Byte

ALM_RD

Description

Command

Response

Processing
classifications

Data communica-
tions command
group

Processing time

6 ms to 2 s

17

05H

05H

• Reads the alarm or warning. This command has the same function as the main

command ALM_RD.

• This command can be used only with the following main commands:

NOP, ID-RD, HOLD, LTMOD_ON/OFF, SMON, SV_ON/OFF,
INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL

18

Substatus

19

ALM_RD_MOD ALM_RD_MOD

20

ALM_DATA

21
22
23
24
25
26
27
28
29

Advertising