3 SERVOPACK Specifications and Dimensional Drawings

3-4

Applicable SERVOPACK Model

SGDS-

12 All Capacities

MECHATROLINK
Communications

Communications
Protocol

MECHATROLINK II

MECHATROLINK

Station Address

41H to 5FH
(Max. number of slaves : 30)

41H to 4FH
(Max. number of slaves : 15)

Transmission Speed

10 Mbps

4 Mbps

Transmission Cycle

250

µs, 05 to 4 ms

(multiple of 0.5 ms)
(In accordance with the setting of the

host controller)

2 ms

Number of Words for
Link Transmission

Can be switched between 17-bytes /
station and 32-bytes / station by the
setting of bit 2 for the SW2 switch.

17-byte / station

Command Method

Performance

Position control, speed control, and
torque control through
MECHATROLINK II communications

Position control through
MECHATROLINK communications

Command Input

MECHATROLINK commands and MECHATROLINK II commands
(For sequence, motion, date setting/reference, monitor, adjustment, and other
commands.)

Functions for
Position Control

Acceleration /
Deceleration
Function

Linear 1st and 2nd step asymmetrical acceleration/deceleration, exponential
function acceleration/deceleration, and movement average acceleration and
deceleration

Fully-closed Control

Position control using the fully-closed feedback is available.

Fully-closed Control
System
Specifications

Interface

Serial communications interface

Power Supply and
Converter for Fully-
closed PG

Provided by the customer.

I/O

Signals

Sequence
Input

Signal allocation
can be modified.

Select any seven of the following signals: forward run prohibited (P-OT), reverse
run prohibited (N-OT), homing deceleration limit switch, external latch signal 1, 2,
3, forward external torque limit, reverse external torque limit

Sequence
Output

Fixed
Output

Alarm

Signal allocation
can be modified.

Select any of the following signals: positioning completion (speed coincidence),
rotation detection, speed limit detection, servo ready, current limit detection, release
brake, warning, NEAR signal

Position
Output

Output

Phase-A, Phase-B, Phase-C: line driver output

Dividing Pulse

Optional dividing pulse

Others

Analog Monitor (CN5)

Output voltage:

±

8 V

Analog monitor connector built in for monitoring speed, torque and other reference
signals.
Speed: 1 V/1000 RPM
Torque: 1 V/rated torque
error pulse: 0.05 V/reference unit

Communi-
cations

Interface

Digital Operator (hand type)

Function

Status display, parameter setting, monitor display, alarm traceback display, JOG
operation