11.2 List of Parameters

11-19

Pn139

Automatic Gain Changeover Related
Switch 1

2

0000

8.6.6

Pn144

Reference Filter Bias (Reverse)

2

0.0 to 1000.0 %

0.1 %

100.0 %

8.6.8

Note:

: Can be changed at any time, and immediately validated after changing. (Called an online

parameter.)

∆: Validated after a Set Up Device command is sent, when loading and using parameters at

power ON. Also validated when turning OFF and then ON the power supply again after a
Write Non-volatile Parameter (PPRM_WR) command is sent.

Parameter

No.

Name

Data

Size

Setting Range

Units

Factory

Setting

Changing

Method

Reference

Section

0

1

0

1

2

3

4

5

Manual gain switching

Automatic gain switching pattern 1
Changes automatically 1st gain to 2nd gain when the switching condition A is satisfied.
Changes automatically 2nd gain to 1st gain when the switching condition B is satisfied.

2 to 4 Reserved (Do not change)

Positioning completion signal (/COIN) ON

Positioning completion signal (/COIN) OFF

NEAR signal (/NEAR) ON

NEAR signal (/NEAR) OFF

Position reference filter output = 0 and Position Reference input = 0

Position reference input

≠ 0

Gain Switching Selection Switch

Gain Switching Condition A

0 to 5 Same as Condition A

Gain Switching Condition B

n.

Reserved (Do not change)

4th

digit

3rd

digit

2nd

digit

1st

digit

Advertising