8 Adjustments

8-50

8.7 Analog Monitor

Signals for analog voltage references can be monitored.
To monitor analog signals, connect the analog monitor cable (JZSP-CA01) to the connector CN5.

Note: The examples shown in the table are factory settings. To change the settings, reset parameters

Pn006 and Pn007.

The output voltages on analog monitor 1 and 2 are calculated by the following equations.

Pin Number

Line Color

Signal Name

Description

1

Red

Analog monitor 2

Motor speed: 1 V/1000 RPM

2

White

Analog monitor 1

Torque reference: 1 V/100

% Rated torque

3,4

Black (2 lines)

GND (0 V)

-

JZSP-CA01

Black

CN5

Black

Red

White

DF0300413 PC

ON

1

POWER

COM

S/N D0024B958810004

Analog monitor 1 output voltage = {(-1)

× Signal selection × Signal multiplier } + Offset voltage [V]

Pn006=

XX

Pn006=

X

Pn550

Analog monitor 2 output voltage = {(-1)

× Signal selection × Signal multiplier } + Offset voltage [V]

Pn007=

XX

Pn007=

X

Pn551