6 MECHATROLINK II Communications

6.3.10 Disconnection (DISCONNECT: 0FH)

6-16

6.3.10 Disconnection (DISCONNECT: 0FH)

Byte

DISCONNECT

Description

Command

Response

1

0FH

0FH

Processing
classifications

Network com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Communications
cycle or more

Subcommand

Cannot be used

3

STATUS

• Releases the MECHATROLINK II connection. The SERVOPACK changes

communication to phase 1.

• Can be used during any phase.
• When this command is received, the following operations will be performed.

- The SERVOPACK changes communication to phase 1.
- The SERVOPACK changes to Servo OFF.
- The reference point setting will become invalid.

• If the control power supply is turned OFF just when sending this command,

a response data will not be able to be sent successfully.