10 disconnection (disconnect: 0fh), 10 disconnection (disconnect, 10 disconnection (disconnect: 0fh) -16 – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 147

6 MECHATROLINK II Communications
6.3.10 Disconnection (DISCONNECT: 0FH)
6-16
6.3.10 Disconnection (DISCONNECT: 0FH)
Byte
DISCONNECT
Description
Command
Response
1
0FH
0FH
Processing
classifications
Network com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Communications
cycle or more
Subcommand
Cannot be used
3
STATUS
• Releases the MECHATROLINK II connection. The SERVOPACK changes
communication to phase 1.
• Can be used during any phase.
• When this command is received, the following operations will be performed.
- The SERVOPACK changes communication to phase 1.
- The SERVOPACK changes to Servo OFF.
- The reference point setting will become invalid.
• If the control power supply is turned OFF just when sending this command,
a response data will not be able to be sent successfully.
4
5
6
7
8
9
10
11
12
13
14
15
16
WDT
RWDT