22 servo on (sv_on: 31h), 22 servo on (sv_on: 31h) -28 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 159

Advertising
background image

6 MECHATROLINK II Communications

6.3.22 Servo ON (SV_ON: 31H)

6-28

6.3.22 Servo ON (SV_ON: 31H)

Byte

SV_ON

Description

Command

Response

1

31H

31H

Processing
classifications

Control com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Use for linear
motors: Within 10
ms
Excluding above
motors :
Within 50 ms

Subcommand

Can be used

3

OPTION

STATUS

• The SERVOPACK changes to Servo ON.
• Can be used during phases 2 and 3.
• Command warning 1 (A.95A) will occur and the command will be ignored in

the following cases.
- During phase 1
- During alarm occurrence (when ALM of STATUS is 1)
- If SENS_ON has not been completed when the absolute encoder is
used

• OPTION field can be selected. Refer to 6.5.2 Option Field Specifications:

OPTION for details.

• When connectiing linear motors not equipped with a pole sensor, it takes 10

seconds max. until the SERVOPACK changes to Servo ON the first time
because the pole must be detected.

• Upon completion of this command, the reference position (POS) must be read,

and the controller coordinate system must be set up.

4
5

MONITOR1

6
7
8
9

MONITOR2

10

11

12
13

SEL_MON 1/2

SEL_MON 1/2

14

IO_MON

15
16

WDT

RWDT

17

For
subcommands.
Refer to 6.4
Subcommands
.

For
subcommands.
Refer to 6.4
Subcommands
.

18
19
20
21
22
23
24
25
26
27
28