6 MECHATROLINK II Communications

6.3.16 Turn Sensor ON (SENS_ON: 23H)

6-22

6.3.16 Turn Sensor ON (SENS_ON: 23H)

Byte

SENS_ON

Description

Command

Response

1

23H

23H

Processing
classifications

Control com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within 1 sec

Subcommand

Cannot be used

3

STATUS

• Obtains the initial position data and creates the present position when an

absolute encoder is used.

• The reference point, home position (ZPOINT), and software limits will be

enabled when an absolute encoder is used.

• Can be used during phases 2 and 3.
• If an incremental encoder is being used, the command will be ignored.
• During phase 1, Command warning 1 (A.95A) will occur and the command

will be ignored.

• After having used this command, the position data must be monitored and the

coordinate system of host controller must be setup.

4
5

MONITOR 1

6
7
8
9

MONITOR 2

10

11

12
13

SEL_MON 1/2

SEL_MON 1/2

14

IO_MON

15
16

WDT

RWDT