6 MECHATROLINK II Communications
6.3.16 Turn Sensor ON (SENS_ON: 23H)
6-22
6.3.16 Turn Sensor ON (SENS_ON: 23H)
Byte
SENS_ON
Description
Command
Response
1
23H
23H
Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within 1 sec
Subcommand
Cannot be used
3
STATUS
• Obtains the initial position data and creates the present position when an
absolute encoder is used.
• The reference point, home position (ZPOINT), and software limits will be
enabled when an absolute encoder is used.
• Can be used during phases 2 and 3.
• If an incremental encoder is being used, the command will be ignored.
• During phase 1, Command warning 1 (A.95A) will occur and the command
will be ignored.
• After having used this command, the position data must be monitored and the
coordinate system of host controller must be setup.