13 set coordinates (pos_set: 20h), 13 set, 13 set coordinates (pos_set: 20h) -19 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 150

Advertising
background image

6.3 Main Commands

6-19

6.3.13 Set Coordinates (POS_SET: 20H)

• Details of PS_SUBCMD

• REFE: Sets reference point.

0: Does not set reference point.
1: Sets reference point.
Decides the coordinates, and ZPOINT and software limits are enabled.

• POS_SEL: Selects coordinates.

3: When APOS (feedback position in machine coordinate system) is selected,
POS_DATA is also set in the reference and machine coordinate system.

Byte

POS_SET

Description

Command

Response

1

20H

20H

Processing
classifications

Data communica-
tions command
group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within communi-
cation cycle

Subcommand

Cannot be used

3

STATUS

• Sets coordinates. REFE can also enable home position (ZPOINT) and

software limits.

• Can be used during phases 2 and 3.
• PS_SUBCMD: Refer to the following table for coordinate setting modes.
• Set position in POS_DATA.
• A warning will occur and the command will be ignored in the following cases.

- During phase 1: Command warning1 (A.95A)
- If a number not within the range is set for PS_SUBCMD: Data setting
warning 2 (A.94B)

4
5

PS_SUBCMD

PS_SUBCMD

6

POS_DATA

POS_DATA

7
8
9

10

11

12
13
14
15
16

WDT

RWDT

D7

D6

D5

D4

D3

D2

D1

D0

REFE

0

0

0

POS_SEL

Advertising