6.2 Switches for MECHATROLINK II Communications Settings
6-5
6.2.3 Setting the Station Address
The station address is set as shown in Table 4.2, using the rotary switch (SW1) and piano switch (SW2 bit 3).
Settings that have been changed are enabled when the power is turned OFF and ON. The factory setting for the
station address is 41H (SW2 bit 3 = OFF, SW1 = 1).
Table 6.2 Station Address Settings
Bit 3 of
SW2
SW1
Station Address
Bit 3 of
SW2
SW1
Station Address
OFF
0
Disabled
ON
0
50H
OFF
1
41H
ON
1
51H
OFF
2
42H
ON
2
52H
OFF
3
43H
ON
3
53H
OFF
4
44H
ON
4
54H
OFF
5
45H
ON
5
55H
OFF
6
46H
ON
6
56H
OFF
7
47H
ON
7
57H
OFF
8
48H
ON
8
58H
OFF
9
49H
ON
9
59H
OFF
A
4AH
ON
A
5AH
OFF
B
4BH
ON
B
5BH
OFF
C
4CH
ON
C
5CH
OFF
D
4DH
ON
D
5DH
OFF
E
4EH
ON
E
5EH
OFF
F
4FH
ON
F
5FH