7 Operation

7.2.4 Supplementary Information on Trial Operation

7-6

7.2.4 Supplementary Information on Trial Operation

(1) Minimum Parameters and Input Signals

This section describes the minimum parameters and input signals required for trial operation.

(a) Parameters

Turn OFF power once after changing any parameter. The change will be valid when power is turned ON
again.

• Changing Servomotor Rotation Direction

Use the following parameter to reverse the direction of rotation.

(b) Input Signals

Refer to the relevant page for details on each input signal.
Input signal selection settings through parameters can be used to eliminate the need for external short cir-
cuits.

(2) Servomotors with Brakes

Use servomotors with brakes for vertical shaft applications or when external force is applied to the shaft to
prevent the shaft from rotating due to gravity or external force when power is lost. The SERVOPACK uses the
brake interlock output (/BK) signal to control holding brake operation when using servomotors with brakes.

To prevent faulty operation due to gravity or external force, make sure that the servomotor and holding
brake operate normally with the servomotor disconnected from the machine. When both of them operate
normally, connect the servomotor to the machine to start trial operation.

The following figure shows wiring for a servomotor with brakes. Refer to 7.6.2 Using the Holding Brake for
details on wiring.

Pn20E

Electronic Gear Ratio (Numerator)

See 7.4.2

Pn210

Electronic Gear Ratio (Denominator)

See 7.4.2

Pn000.0

Function Selection Basic Switches: Direction Selection

See 7.3.1

Signal Name

Pin

Number

Description

P-OT

Forward run
prohibited

CN1-7

The Overtravel Limit Switch
Refer to 7.3.2.

N-OT

Reverse run
prohibited

CN1-8

Servomotor

Holding brake

Prevents the

servomotor from

rotating due to gravity .

Servomotor

External

force

Vertical Shaft

Shaft with External Force Applied

IMPORTANT