8.6 Servo Gain Adjustment Functions

8-41

Pn1A2

Speed Feedback Filter Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.30 to 32.00 ms

0.01 ms

0.72 ms

Immediately

Pn1A3

Speed Feedback Filter Time Constant #2

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.30 to 32.00 ms

0.01 ms

0.72 ms

Immediately

Pn1A4

Torque Reference Filter Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.00 to 25.00 ms

0.01 ms

0.36 ms

Immediately

Pn1A9

Auxiliary Integral Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 500 Hz

1 Hz

37 Hz

Immediately

Pn1AA

Position Proportional Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 500 Hz

1 Hz

60 Hz

Immediately

Pn1AB

Speed Integral Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 500 Hz

1 Hz

0 Hz

Immediately

Pn1AC

Speed Proportional Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 2,000 Hz

1 Hz

120 Hz

Immediately

Pn10B

Gain-related Application Switches

Setting Range

Setting Unit

Factory Setting

Setting Validation

0000

After restart

Pn1A7

Auxiliary Control Switches

Setting Range

Setting Unit

Factory Setting

Setting Validation

1121

Immediately

Position

Position

Position

Position

Position

Position

Position

Position