4 400 v power supply voltage, 4 400 v power supply voltage -23, Caution – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 126

Advertising
background image

5.6 Others

5-23

5.6.4 400 V Power Supply Voltage

When using SERVOPACK with the three-phase 400-VAC class (380 V to 480 V), prepare the following voltage
conversion transfers (single-phase or three-phase).

When selecting a voltage conversion transfer, refer to the capacities shown in the following table.

* This is the net value at the rated load.

Single-phase Power Supply Connection Example

• Do not connect the SERVOPACK for 100 V and 200 V directly to a voltage of 400 V.

The SERVOPACK will be destroyed.

• Control the AC power supply ON and OFF sequence at the primary side of voltage conversion transfer.

Voltage conversion transfer inductance will cause a surge voltage if the power is turned ON and OFF at the secondary,
damaging the SERVOPACK.

CAUTION

Primary Voltage

Secondary Voltage

380 to 480 VAC
380 to 480 VAC

→
→

200 VAC
100 VAC

Voltage

SERVOPACK

Model

Voltage Capacity per

SERVOPACK * (kVA)

Current Capacity of Circuit

braker or Fuse (Arms)

Single-phase
100 V

SGDS-A5F

0.25

4

SGDS-01F

0.40

4

SGDS-02F

0.60

6

SGDS-04F

1.20

8

Single-phase
200 V

SGDS-A5A

0.25

4

SGDS-01A

0.40

4

SGDS-02A

0.75

4

SGDS-04A

1.2

8

SGDS-08A

2.1

11

Three-phase
200 V

SGDS-10A

2.3

7

SGDS-15A

3.2

10

SGDS-20A

4.3

13

SGDS-30A

5.9

17

Single-phase

R

S

T

1KM

1KM

Magnetic contactor for
power supply ON and OFF

Voltage conversion
transfer

100 or 200 VAC

SERVOPACK

YASKAWA SERVOPACK 2 0 0 V

S G D S - 0 2 A 1 2 A

SW1

CHARGE

L1

L2

L1C

L2C

B1/

B2

U

V

W

C

N

6

C

N

3

C

N

1

C
N
2

C
N
4

A / B

L1

L2

Advertising