4 400 v power supply voltage, 4 400 v power supply voltage -23, Caution – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 126

Advertising
background image

5.6 Others

5-23

5.6.4 400 V Power Supply Voltage

When using SERVOPACK with the three-phase 400-VAC class (380 V to 480 V), prepare the following voltage
conversion transfers (single-phase or three-phase).

When selecting a voltage conversion transfer, refer to the capacities shown in the following table.

* This is the net value at the rated load.

Single-phase Power Supply Connection Example

• Do not connect the SERVOPACK for 100 V and 200 V directly to a voltage of 400 V.

The SERVOPACK will be destroyed.

• Control the AC power supply ON and OFF sequence at the primary side of voltage conversion transfer.

Voltage conversion transfer inductance will cause a surge voltage if the power is turned ON and OFF at the secondary,
damaging the SERVOPACK.

CAUTION

Primary Voltage

Secondary Voltage

380 to 480 VAC
380 to 480 VAC


200 VAC
100 VAC

Voltage

SERVOPACK

Model

Voltage Capacity per

SERVOPACK * (kVA)

Current Capacity of Circuit

braker or Fuse (Arms)

Single-phase
100 V

SGDS-A5F

0.25

4

SGDS-01F

0.40

4

SGDS-02F

0.60

6

SGDS-04F

1.20

8

Single-phase
200 V

SGDS-A5A

0.25

4

SGDS-01A

0.40

4

SGDS-02A

0.75

4

SGDS-04A

1.2

8

SGDS-08A

2.1

11

Three-phase
200 V

SGDS-10A

2.3

7

SGDS-15A

3.2

10

SGDS-20A

4.3

13

SGDS-30A

5.9

17

Single-phase

R

S

T

1KM

1KM

Magnetic contactor for
power supply ON and OFF

Voltage conversion
transfer

100 or 200 VAC

SERVOPACK

YASKAWA SERVOPACK 2 0 0 V

S G D S - 0 2 A 1 2 A

SW1

CHARGE

L1

L2

L1C

L2C

B1/

B2

U

V

W

C

N

6

C

N

3

C

N

1

C
N
2

C
N
4

A / B

L1

L2

Advertising