6.3 Main Commands
6-21
6.3.15 Release Brake (BRK_OFF: 22H)
• Related Parameter
Byte
BRK_OFF
Description
Command
Response
1
22H
22H
Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within communi-
cations cycle
Subcommand
Cannot be used
3
STATUS
• Applies brake. This command is enabled when Pn50F.2
is set to 1.
• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the following cases.
- During phase 1: Command warning 1 (A.95A)
- If Pn50F.2 is set to 0: Command warning 3 (A.95C)
• Brake signal output timing
4
5
MONITOR 1
6
7
8
9
MONITOR 2
10
11
12
13
SEL_MON1/2
SEL_MON1/2
14
IO_MON
15
16
WDT
RWDT
Pn No.
Description
Pn50F.2
/BK signal
Within 3 ms