6.3 Main Commands

6-21

6.3.15 Release Brake (BRK_OFF: 22H)

• Related Parameter

Byte

BRK_OFF

Description

Command

Response

1

22H

22H

Processing
classifications

Control com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within communi-
cations cycle

Subcommand

Cannot be used

3

STATUS

• Applies brake. This command is enabled when Pn50F.2

is set to 1.

• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the following cases.

- During phase 1: Command warning 1 (A.95A)
- If Pn50F.2 is set to 0: Command warning 3 (A.95C)

• Brake signal output timing

4
5

MONITOR 1

6
7
8
9

MONITOR 2

10

11

12
13

SEL_MON1/2

SEL_MON1/2

14

IO_MON

15
16

WDT

RWDT

Pn No.

Description

Pn50F.2

/BK signal

Within 3 ms