3 write parameter (prm_wr: 02h), 3 write parameter (prm_wr: 02h) -8 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 139

Advertising
background image

6 MECHATROLINK II Communications

6.3.3 Write Parameter (PRM_WR: 02H)

6-8

6.3.3 Write Parameter (PRM_WR: 02H)

Byte

PRM_WR

Description

Command

Response

1

02H

02H

Processing
classifications

Data communica-
tions command
group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Refer to the fol-
lowing table

Subcommand

Cannot be used

3

STATUS

• Temporarily writes parameters and does not store them in E

2

PROM memory.

Offline parameters are enabled with the Set Up Device command (CONFIG)
transmission after setting.

• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the following cases.

- During phases other than phases 2 and 3:
Command warning1 (A.95A)
- If a Digital Operator is connected: Command warning 1 (A.95A)
- If NO is not within range: Data setting warning 4 (A.94D)
- If SIZE does not match: Data setting warning 2 (A.94B)
- If PARAMETER is not within range: Data setting warning 2 (A.94B)
- A calculation error: Data setting warning 3 (A.94C)

• For details on NO, SIZE, and PARAMETER, refer to 11.2.2 List of

Parameters.

4
5

NO

NO

6
7

SIZE

SIZE

8

PARAMETER

PARAMETER

9

10

11

12
13
14
15
16

WDT

RWDT