6.5 Command Data Field

6-53

* For the items to be monitored, assign their monitor codes to the SEL_MON commands.(, 1 to 4)

6.5.5 IO Monitor Field Specifications: IO_MON

The IO monitor field specifications (IO_MON) can be designated using the following commands:
SMON, SV_ON, SV_OFF, HOLD, INTERPOLATE, FEED, POSING, LATCH, EX_POSING, ZRET,
VELCTRL, TRQCTRL, SENS_ON, SENS_OFF, BRK_ON, BRK_OFF, LTMOD-ON, LTMOD-OFF
The IO monitor field is used to monitor the I/O signal status of the SERVOPACK, with the fourteenth to fifteenth
byte reserved area of the above main commands.

• IO Monitor Field

7
8

FSPD

Feedback speed

Position/torque control: reference units/s
Speed control: Maximum speed /40000000H

9

CSPD

Reference speed

Position/torque control: reference units/s
Speed control: Maximum speed /40000000H

A

TSPD

Target speed

Position/torque control: reference units/s
Speed control: Maximum speed /40000000H

B

TRQ

Torque reference (The rated torque is 100%.) Position/torque control: %

Speed control: Maximum torque /
40000000H

C
D
E

OMN1

Option monitor 1 selected in Pn824

F

OMN2

Option monitor 2 selected in Pn825

Monitor

Codes*

Name

Description

Unit

D7

D6

D5

D4

D3

D2

D1

D0

EXT2

EXT1

PC

PB

PA

DEC

N_OT

P_OT

D15

D14

D13

D12

D11

D10

D9

D8

IO15

IO14

IO13

IO12

BRK

EXT3

Bit

Name

Description

Set

Value

Settings

D0

P_OT

Forward run prohibited input

0

OFF

1

ON

D1

N_OT

Reverse run prohibited input

0

OFF

1

ON

D2

DEC

Homing deceleration LS input

0

OFF

1

ON

D3

PA

Encoder phase A input

0

OFF

1

ON

D4

PB

Encoder phase B input

0

OFF

1

ON

D5

PC

Encoder phase C input

0

OFF

1

ON

D6

EXT1

First external latch signal input

0

OFF

1

ON

D7

EXT2

Second external latch signal input

0

OFF

1

ON

Advertising