4.4 Communications Modules

— 4-179 —

3) System Configuration

Slot No.

Rack 1 (CPU Rack)

To another VIO

To another VIO

24-V external

power supply

VINUS I/O

System

VINUS I/O System

transmission line

(twisted-pair cable)

VIOD:

Distributed I/O Driver Module

VIO:

Distributed I/O Module

T:

Terminator

MB12:

12-slot Mounting Base

PS10:

Power Supply Module (7A)

CPU30: CPU Module (32 kW)

24-V external

power supply

24-V external

power supply

Figure 4.51 VINUS System Configuration Example

4) MECHATROLINK Port

A Distributed I/O Driver Module connected to the MECHATROLINK port can perform
high-speed communications at a baud rate of 4 Mbps with up to 30 Distributed I/O Mod-
ules (slaves) over a transmission distance of up to 200 m.