3.1

Overview of System Components

— 3-7 —

Product

Number

of Slots

Required

Features

Model

Number

Model Name

Name

Commu-

nica-

tions

Mod-

ules,

contin-

ued

M-NET

Module

M-NET

JAMSC-

120NMN31000

1) Used for high-speed data communications

between PLCs.

2) Serves as a station of the M-NET System.

3) Up to 15 M-NET Modules (slaves) can be

connected to each M-NET Module (master).

4) Can be connected to GL60S and U84

M-NET Modules.

5) Uses special M-NET cables as transmission

cables.

6) Can be mounted to any Rack.

1

YENET

1600-D

Module

YENET

1600-D

JAMSC-

120NDN31110

1) Used for high-speed data communications

between PLCs.

2) Serves as a station of the YENET 1600-D

System.

3) Up to 63 YENET 1600-D Modules (slaves)

can be connected to each YENET 1600-D
Module (master).

4) Can be connected to masters and slaves

conforming to the DeviceNet protocol.

5) Uses special YENET 1600-D cables as

transmission cables.

6) Can be mounted to any Rack.

1

Ethernet

Interface

Module

EIF

JAMSC-

120NET12100

1) Used for data communications between

PLCs.

2) Serves as an interface for connections in

Ethernet network systems.

3) Communications supported for up to 19

connections for each Ethernet Interface
Module.

4) Provides a 10Base5 port and a 10Base-T

port.

5) Mounted to CPU Rack.

1

3