System Components: Functions and Specifications

— 4-300 —

4.10 Rack-to-rack I/O Cables

This section describes the appearance, application, models and specifications of the
Rack-to-rack I/O Cables.

1) Appearance

Shielded cable

Model name

Connector 1

Connector 2

2) Applications

Rack-to-rack I/O Cables are used to connect two Expander Modules between two adja-
cent Racks.

3) Models and Specifications

The models and specifications of the Rack-to-rack I/O Cables are shown in the following
table.

Table 4.120 Models and Specifications of Rack-to-rack I/O Cable

Item

Specifications

Model Name

W0100-02

W0100-05

W0100-10

W0100-50

Model No.

JZMSZ-120W0

100-02

JZMSZ-120W0

100-05

JZMSZ-120W0

100-10

JZMSZ-120W0

100-50

Length (L)

0.2 m

0.5 m

1.0 m

5.0 m

Approx. Mass

80 g

100 g

150 g

450 g

Cable Specifications

26-core shielded cable, equivalent to UL20276, 0.08 mm

2

(AWG 28).

Connector Specifications

10126-6000EL + 10326-A500-00 (3M)

Connector 1 and connector 2 have the same specifications.

4) Application

a) More than one Rack-to-rack I/O Cable can be used at the same station; however, the

following conditions must be met:

(1) A maximum of 3 can be used.

(2) The total length of cables must not exceed 6.0 m.