System Components: Functions and Specifications

4.7.4 Two-axis Motion Module cont.

— 4-272 —

c) Based on the limits to the number of I/O references above, the maximum number of

Two-axis Motion Modules that can be used depends on the CPU Module, as shown
below.

Maximum Number of Two-axis Motion Modules that Can Be Used

CPU Module

Input Relays

and

Output Coils

Input

Registers and

Output

Registers

Max. No. of

MC15

Modules

Remarks

CPU20

CPU21

1,024

512

8

D

All input relays and
output coils will be used
for the MC15 Modules.

D

There will be 64 unused
I/O registers

CPU30

CPU35

4,096

512

16

D

There will be 2,944
unused input relays and
output coils.

D

There will be 8 unused
I/O registers.

Note

(1) When using Remote Stations, the limit is 8 Modules for the CPU20 and CPU21 and 12

Modules for the CPU30 and CPU35

(2) When using a PS10 or PS11 Power Supply Module, a single Two-axis Motion Module

uses 750 mA of the 7 A current available, so a maximum of 9 Modules can be used per
Rack.

2) Installation Locations

a) The Two-axis Motion Module requires one slot and can be mounted as shown below.

(1) If not using the absolute position detecting function, the Module can be mounted

to any slot on any Rack.

(2) If using the absolute position detecting function, the Module can be mounted to

any slot on the Mounting Base of the CPU Rack.