4.7 Motion Modules

— 4-267 —

Item

Specifications

Mounting

Location

Not using absolute encoder: Any slot of any rack.

Using absolute encoder: Any slot of CPU Rack.

Supported CPU

Modules

CPU20 (16 KW), CPU21 (16 KW), CPU30 (32 KW), CPU35 (40 KW)

Servo Interface

Signals

The following signals can be input from or output to a servo amp via the servo connectors on the

front panel of the Module.

1) Input Signals

a) Feedback Input

5-V differential line driver or 5-V open collector output, phase A/B/C/S, maximum frequency:
1 Mpps (1X). Line breakage detection: None.

b) Servo Alarm Input

Source input, 24 VDC, 5 mA, photocoupler isolation.

2) Output Signals

a) Position Reference Output (CW and CCW)

Sign + pulse mode or CCW + CW mode.
Pulse output speed: 0 to 500 kpps
Pulse output format: Open-collector output

b) Battery Output

Connect to battery input on absolute SERVOPACK.

c) SEN Signal Output

Connect to SEN input on absolute SERVOPACK. 5 VDC, 5 mA.

d) Servo ON Output

24 VDC, 15 mA, photocoupler isolation, open-collector output (sinking output).

e) Servo Alarm Reset Output

24 VDC, 15 mA, photocoupler isolation, open-collector output (sinking output).

f) Error Counter Clear Output

24 VDC, 15 mA, photocoupler isolation, open-collector output (sinking output).

Stepping Motor

Interface

Signals

The following signals can be input and output with one Stepping Motor Driver per servo connector

via the Servo Connectors on the front panel of the Module.

1) Input Signals

a) Overheating Input

5 VDC, 5 mA, photocoupler isolation.

2) Output Signals

a) Position Reference Output (CW and CCW)

Sign + pulse mode or CCW + CW mode.
Pulse output speed: 0 to 500 kpps
Pulse output format: Open-collector output

b) Output Voltage OFF Output

5 VDC, 15 mA, photocoupler isolation, open-collector output (sinking output).