+CIND - Indicator Control

SELINT 2

<ind> - roaming indicator range
0 - registered to home network or not registered
1 - registered to other network
“smsfull” - a short message memory storage in the MT has become full (1),

or memory locations are available (0)

<ind> - short message memory storage indicator range
0 - memory locations are available
1 - a short message memory storage in the MT has become full.
“rssi” - received signal (field) strength
<ind> - received signal strength level indicator range
0 - signal strength ≤ (-112) dBm
1..4 - signal strength in (-97) dBm..(-66) dBm (15 dBm steps)
5 - signal strength ≥ (-51) dBm
99 - not measurable

Example

Next command causes all the indicators to be registered

AT+CIND=1,1,1,1,1,1,1,1,1
Next command causes all the indicators to be de-
registered

AT+CIND=0,0,0,0,0,0,0,0,0
Next command to query the current value of all
indicators

AT+CIND?
CIND: 4,0,1,0,0,0,0,0,2

OK

Note See

command

+CMER

Reference GSM

07.07

3.5.4.4.6 Mobile Equipment Event Reporting - +CMER

+CMER - Mobile Equipment Event Reporting

SELINT 2

AT+CMER=
[<mode>
[,<keyp>
[,<disp>
[,<ind>
[,<bfr>]]]]]

Set command enables/disables sending of unsolicited result codes from
TA to TE in the case of indicator state changes (n.b.: sending of URCs in
the case of key pressings or display changes are currently not
implemented).

Parameters:
<mode> - controls the processing of unsolicited result codes
0 - discard +CIEV Unsolicited Result Codes.
1 - discard +CIEV Unsolicited Result Codes when TA-TE link is reserved

(e.g. on-line data mode); otherwise forward them directly to the TE.

2 - buffer +CIEV Unsolicited Result Codes in the TA when TA-TE link is

reserved (e.g. on-line data mode) and flush them to the TE after
reservation; otherwise forward them directly to the TE.

3 - forward +CIEV Unsolicited Result Codes directly to the TE; when TA is

in on-line data mode each +CIEV URC is replaced with a Break (100
ms), and is stored in a buffer; onche the ME goes into command mode

Advertising