7 change facility password - +cpwd – Rainbow Electronics GM862-QUAD-PY User Manual
Page 91

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 91 of 434
@CLCK - Facility Improved Lock/Unlock
SELINT 0 / 1
Example
Querying such a facility returns an output on three
rows, the first for voice, the second for data, the
third for fax:
AT@CLCK =”AO”,2
@CLCK: <status>,1
@CLCK: <status>,2
@CLCK: <status>,4
OK
3.5.4.3.7 Change Facility Password - +CPWD
+CPWD - Change Facility Password
SELINT 0 / 1
AT+CPWD=<fac>,
<oldpwd>,
<newpwd>
Execution command changes the password for the facility lock function
defined by command Facility Lock +CLCK.
Parameters:
<fac> - facility
“SC” - SIM (PIN request)
“AB” - All barring services
“P2” - SIM PIN2
<oldpwd> - string type, it shall be the same as password specified for the
facility from the ME user interface or with command +CPWD.
<newpwd> - string type, it is the new password
Note: parameter <oldpwd> is the old password while <newpwd> is the new
one.
AT+CPWD=?
Test command returns a list of pairs (<fac>,<pwdlength>) which presents
the available facilities and the maximum length of their password
(<pwdlength>)
Example
at+cpwd=?
+CPWD: ("SC",8),("AB",4),("P2",4)
OK
Reference GSM
07.07
+CPWD - Change Facility Password
SELINT 2
AT+CPWD=<fac>,
<oldpwd>,
<newpwd>
Execution command changes the password for the facility lock function
defined by command Facility Lock +CLCK.
Parameters:
<fac> - facility
“SC” - SIM (PIN request)
“AB” - All barring services
“P2” - SIM PIN2