AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 315 of 434

#NWSCANTMR: <tmr>

AT#NWSCANTMR=? Test command reports the supported range of values for parameter <tmr>

Note

How much time it takes to execute the network scan depends either on how
much bands have been selected and on network configuration (mean value
is 5 seconds)


3.5.7.2 General Configuration AT Commands - Special Issues

Following commands are available only for specific subsets of products, as it appears in the ‘Note’

3.5.7.2.1 External 32kHz Oscillator

#OSC32KHZ - External 32kHz Oscillator

SELINT 2

AT#OSC32KHZ

Execution command reports the presence of an external 32kHz oscillator, in
the format:

#OSC32KHZ: <stat>

where:
<stat>
0 - external 32kHz oscillator is not present
1 - external 32kHz oscillator is present

Note: if the external oscillator is removed while the module is on, the
software will take up to 9 seconds to realize its absence.

Note: if the external oscillator is connected to the module while it is on, the
software will take less than 1 second to realize its presence.

AT#OSC32KHZ=?

Test command returns the OK result code.

Note

This command is currently available only for the product GE864-AUTO


3.5.7.3 Multisocket AT Commands

3.5.7.3.1 Socket Status - #SS

#SS - Socket Status

SELINT 2

AT#SS

Execution command reports the current status of the sockets in the format:

#SS: <connId>,<state>,<locIP>,<locPort>,<remIP>,<remPort>
[<CR><LF><connId>,<state>,<locIP>,<locPort>,<remIP>,<remPort>
[…]]

where: