Rainbow Electronics GM862-QUAD-PY User Manual

Page 413

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 413 of 434

#STARTMODESCR - Script Execution Start Mode

SELINT 0 / 1

10..60 - time interval in seconds; this parameter is used only if

parameter <script_start_mode> is set to 1; it is the waiting
time for an AT command on the serial port to disable active
script execution start. If the user does not send any AT
command on the serial port for the time specified in this
parameter active script will not be executed (default is 10).

Note: issuing AT#STARTMODESCR<CR> is the same as issuing the
Read command.

AT#STARTMODESCR?

Read command reports the current script start mode and the current
script
start time-out, in the format:

#STARTMODESCR= <script_start_mode>,<script_start_timeout>

AT#STARTMODESCR=? Test command returns the range of available values for parameters

<script_start_mode> and <script_start_timeout>, in the format:

#STARTMODESCR: (0,2),(10-60)


#STARTMODESCR - Script Execution Start Mode

SELINT 2

AT#STARTMODESCR=
<script_start_mode>
[,<script_start_to>]

Set command sets the current script (see #ESCRIPT) execution
start mode.

Parameter:
<script_start_mode> - currente script execution start mode

0 - current script will be executed at startup only if the DTR line is

found Low (that is: COM is not open on a PC), otherwise the Easy
Script® interpreter will not execute and the MODULE will behave
normally answering only to AT commands on the serial port
(factory default).

1 - current script will be executed at startup only if the user does not

send any AT command on the serial port for the time interval
specified in <script_start_to> parameter, otherwise the Easy
Script® interpreter will not execute and the MODULE will behave
normally answering only to AT commands on the serial port. The
DTR line is not tested.

2 - current script will be executed at startup in any case apart from

DTR line and if the user does not send any AT command on the
serial port for the time interval specified in <script_start_to>
parameter. But AT command interface will be available on serial
port ASC0 and connected to third AT parser instance.


<script_start_to>
- current script start time-out;
10..60 - time interval in seconds; this parameter is used only if

parameter <script_start_mode> is set to 1; it is the waiting
time for an AT command on the serial port to disable active
script execution start. If the user does not send any AT
command on the serial port for the time specified in this

Advertising