#VAUX- Auxiliary Voltage Output Control

SELINT 0 / 1


Note: when <stat>=2 and command is successful, it returns:

#VAUX: <value>

where:
<value> - power output status
0 - output off
1 - output on


Note: If all parameters are omitted the command has the same behaviour
as Read command.

Note: for the GPS product (GE863-GPS): if the Auxiliary Voltage pin output
is disabled while GPS is powered on they’ll both also be turned off.

AT#VAUX?

Read command reports whether the Auxiliary Voltage pin output is currently
enabled or not, in the format:

#VAUX: <value>

AT#VAUX=?

Test command reports the supported range of values for parameters <n>,
<stat>.


#VAUX- Auxiliary Voltage Output Control

SELINT 2

AT#VAUX=
[<n>,<stat>]

Set command enables/disables the Auxiliary Voltage pins output.

Parameters:
<n> - VAUX pin index

1 - there is currently just one VAUX pin

<stat>
0 - output off
1 - output on
2 - query current value of VAUX pin

Note: when <stat>=2 and command is successful, it returns:

#VAUX: <value>

where:
<value> - power output status
0 - output off
1 - output on

Note: for the GPS product (GE863-GPS): if the Auxiliary Voltage pins output
is disabled while GPS is powered on they’ll both also be turned off.

Note: the current setting is stored through #VAUXSAV