AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 273 of 434

#MSCLASS - Multislot Class Control

SELINT 2


Note: the <class> range for former GM862 family products is 1..8,
excluding class 7.

AT#MSCLASS?

Read command reports the current value of the multislot class in the
format:
#MSCLASS: <class>

AT#MSCLASS=?

Test command reports the range of available values for both parameters
<class> and <autoattach>.

3.5.7.1.43 Cell Monitor - #MONI

#MONI - Cell Monitor

SELINT 0 / 1

AT#MONI[=
[<number>]]

#MONI is both a set and an execution command.

Set command sets one cell out of seven, in a neighbour of the serving cell
including it, from which extract GSM-related information.

Parameter:
<number>
0..6 - it is the ordinal number of a cell, in a neighbour of the serving cell

(default 0, serving cell).

7 - it is a special request to obtain GSM-related informations from the

whole set of seven cells in the neighbour of the serving cell.


Note: issuing AT#MONI<CR> is the same as issuing the Read command.

Note: issuing AT#MONI=<CR> is the same as issuing the command
AT#MONI=0<CR>.

AT#MONI?

Execution command reports GSM-related informations for selected cell
and dedicated channel (if exists).

a) When extracting data for the serving cell and the network name is

known the format is:
#MONI: <netname> BSIC:<bsic> RxQual:<qual> LAC:<lac>
Id:<id> ARFCN:<arfcn> PWR:<dBm> dBm TA: <timadv>

b) When the network name is unknown, the format is:

#MONI: Cc:<cc> Nc:<nc> BSIC:<bsic> RxQual:<qual> LAC:<lac>
Id:<id> ARFCN:<arfcn> PWR:<dBm> dBm TA: <timadv>

c) When extracting data for an adjacent cell, the format is:

#MONI: Adj Cell<n> [LAC:<lac> Id:<id>] ARFCN:<arfcn>
PWR:<dBm> dBm

where:
<netname> - name of network operator