5 response formatting character - s4 – Rainbow Electronics GM862-QUAD-PY User Manual

Page 62

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 62 of 434

S3 - Command Line Termination Character

SELINT 2


Note: the “previous” value of S3 is used to determine the command line
termination character for entering the command line containing the S3
setting command. However the result code issued shall use the “new” value
of S3 (as set during the processing of the command line)

ATS3?

Read command returns the current value of S3 parameter.

Note: the format of the numbers in output is always 3 digits, left-filled with 0s

Reference V25ter

3.5.3.7.5 Response Formatting Character - S4

S4 - Response Formatting Character

SELINT 0 / 1

ATS4[=<char>]

Set command sets the value of the character generated by the device as
part of the header, trailer, and terminator for result codes and information
text, along with the S3 parameter.

Parameter:
<char> - response formatting character (decimal ASCII)
0..127 - factory default value is 10 (ASCII LF)

Note: if the value of S4 is changed in a command line the result code issued
in response of that command line will use the new value of S4.

ATS4?

Read command returns the current value of S4 parameter.

ATS4=?

Test command returns the range for <char> without command echo and
parenthesis

Note

For either Read and Test command the format of the numbers in output is
always 3 digits, left-filled with 0s

Reference V25ter

S4 - Response Formatting Character

SELINT 2

ATS4=[<char>]

Set command sets the value of the character generated by the device as
part of the header, trailer, and terminator for result codes and information
text, along with the S3 parameter.

Parameter:
<char> - response formatting character (decimal ASCII)
0..127 - factory default value is 10 (ASCII LF)

Note: if the value of S4 is changed in a command line the result code issued
in response of that command line will use the new value of S4.

ATS4?

Read command returns the current value of S4 parameter.

Note: the format of the numbers in output is always 3 digits, left-filled with 0s

Reference V25ter

Advertising