11 select ringer sound - #srs – Rainbow Electronics GM862-QUAD-PY User Manual
Page 243

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 243 of 434
#CAP - Change Audio Path
SELINT 0 / 1
AT#CAP?
Read command reports the active audio path in the format:
#CAP: <n>.
AT#CAP=?
Test command reports the supported values for the parameter <n>.
#CAP - Change Audio Path
SELINT2
AT#CAP=[<n>]
Set command switches the active audio path depending on parameter <n>
Parameter:
<n> - audio path
0 - audio path follows the AXE input (factory default):
• if AXE is low, handsfree is enabled;
• if AXE is high, internal path is enabled
1 - enables handsfree external mic/ear audio path
2 - enables internal mic/ear audio path
Note: The audio path are mutually exclusive, enabling one disables the
other.
Note: when changing the audio path, the volume level is set at the
previously stored value for that audio path (see +CLVL).
AT#CAP?
Read command reports the active audio path in the format:
#CAP: <n>.
AT#CAP=?
Test command reports the supported values for the parameter <n>.
3.5.7.1.11 Select Ringer Sound - #SRS
#SRS - Select Ringer Sound
SELINT 0 / 1
AT#SRS[=
<n>,<tout>]
Set command sets the ringer sound.
Parameters:
<n> - ringing tone
0 - current ringing tone
1..max - ringing tone number, where max can be read by issuing the Test
command AT#SRS=?.
<tout> - ringing tone playing time-out in seconds.
0 - ringer is stopped (if present) and current ringer sound is set.
1..60 - ringer sound playing for <tout> seconds and, if <n> > 0, ringer
sound <n> is set as default ringer sound.
Note: when the command is issued with <n> > 0 and <tout> > 0, the <n>
ringing tone is played for <tout> seconds and stored as default ringing tone.
Note: if command is issued with <n> > 0 and <tout> = 0, the playing of the
ringing is stopped (if present) and <n> ringing tone is set as current.