3.4 AT Commands Availability Table


The following table lists the AT commands set and matches the availability of every single command
versus the Telit wireless module family. It deals with backward compatibility issues too, showing the
availability of every single command depending on selected interface style (#SELINT).


COMMAND

GM862

-

QUAD

GM862-

QUAD-

PY

GM862-

GPS

GE863-

QUAD

&GE863-

PRO

3

GE863-

PY &

GE863-

SIM

GE863-

GPS

GE864-

AUTO

GE864-

QUAD

&

GC864-

QUAD

GC864-

PY

&

GE864-

PY

Function

Page

Command Line General Format - Command Line Prefixes

AT

Starting A Command Line

31

A/

Last Command Automatic Repetition Prefix

31

General Configuration Commands - AT Interface Backward Compatibility

#SELINT

12

Select Interface Style

33

Hayes AT Commands - Generic Modem Control

&F

Set To Factory-Defined Configuration

34

Z

Soft Reset

34

+FCLASS

Select Active Service Class

34

&Y

Designate A Default Reset Basic Profile

35

&P

Designate A Default Reset Full Profile

35

&W

Store Current Configuration

36

&Z

Store Telephone Number In The Module
Internal Phonebook

36

&N

Display Internal Phonebook Stored Numbers

36

+GMI

Manufacturer Identification

36

+GMM

Model Identification

37

+GMR

Revision Identification

37

+GCAP

Capabilities List

37

+GSN

Serial Number

37

&V

Display Current Base Configuration And
Profile

37

&V0

Display Current Configuration And Profile

38

&V1

S Registers Display

38

&V3

Extended S Registers Display

38

&V2

Display Last Connection Statistics

39

\V

Single Line Connect Message

39

+GCI

Country Of Installation

39

%L

Line Signal Level

39

%Q

Line Quality

40

L

Speaker Loudness

40

M

Speaker Mode

40

Hayes AT Commands - DTE-Modem Interface Control

E

Command Echo

40

Q

Quiet Result Codes

40

V

Response Format

41

X

Extended Result Codes

42

I

Identification Information

43

&C

Data Carrier Detect (DCD) Control

43

&D

Data Terminal Ready (DTR) Control

43

\Q

Standard Flow Control

45

12

GE863-PRO3 does not support selint command