#E2ESC - Escape Sequence Guard Time
SELINT 0 / 1
AT#E2ESC[=
[<gt>]]
Set command sets a guard time in seconds for the escape sequence in
GPRS to be considered a valid one (and return to on-line command mode).
Parameter:
<gt>
0 - guard time defined by command S12 (factory default)
1..10 - guard time in seconds
Note: if the Escape Sequence Guard Time is set to a value different from
zero, it overrides the one set with S12.
Note: issuing AT#E2ESC<CR> is the same as issuing the Read command.
Note: issuing AT#E2ESC=<CR> returns the OK result code.
AT#E2ESC?
Read command returns current value of the escape sequence guard time,
in the format:
#E2ESC: <gt>
AT#E2ESC=?
Test command returns the OK result code.
#E2ESC - Escape Sequence Guard Time
SELINT 2
AT#E2ESC=
[<gt>]
Set command sets a guard time in seconds for the escape sequence in
GPRS to be considered a valid one (and return to on-line command mode).
Parameter:
<gt>
0 - guard time defined by command S12 (factory default)
1..10 - guard time in seconds
Note: if the Escape Sequence Guard Time is set to a value different from
zero, it overrides the one set with S12.
AT#E2ESC?
Read command returns current value of the escape sequence guard time,
in the format:
#E2ESC: <gt>
AT#E2ESC=?
Test command returns the OK result code.
3.5.7.1.79 PPP-GPRS Connection Authentication Type - #GAUTH
#GAUTH - PPP-GPRS Connection Authentication Type
SELINT 0 / 1
AT#GAUTH[=
<type>]
Set command sets the authentication type either for PPP-GPRS and PPP-
GSM connections.
Parameter
<type>