Rainbow Electronics GM862-QUAD-PY User Manual
Page 140

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 140 of 434
+CRSL - Ringer Sound Level
SELINT 0
1 - low
2 - middle
3 - high
4 - progressive
Note: if parameter is omitted then the behaviour of Set command is the
same as Read command
AT+CRSL?
Read command reports the current <level> setting of the call ringer in the
format:
+CRSL: <level>
AT+CRSL=?
Test command reports <level> supported values as compound value.
For compatibility with previous versions, Test command returns
+CRSL: (0-3)
An enhanced version of Test command has been defined: AT+CRSL=??,
that provides the complete range of values for <level>.
AT+CRSL=??
Enhanced Test command returns the complete range of supported values
for the parameter <mode>:
+CRSL: (0-4)
Reference GSM
07.07
+CRSL - Ringer Sound Level
SELINT 1
AT+CRSL[=
<level>]
Set command is used to select the incoming call ringer sound level of the
device.
Parameter:
<level> - ringer sound level
0 - Off
1 - low
2 - middle
3 - high
4 - progressive
Note: if parameter is omitted then the behaviour of Set command is the
same as Read command
AT+CRSL?
Read command reports the current <level> setting of the call ringer in the
format:
+CRSL: <level>
AT+CRSL=?
Test command reports <level> supported values as compound value, in the
format:
+CRSL: (0-4)