+CPWD - Change Facility Password

SELINT 2

“PS”- SIM VO

<oldpwd> - string type, it shall be the same as password specified for the

facility from the ME user interface or with command +CPWD.

<newpwd> - string type, it is the new password

Note: parameter <oldpwd> is the old password while <newpwd> is the new
one.

AT+CPWD=?

Test command returns a list of pairs (<fac>,<pwdlength>) which presents
the available facilities and the maximum length of their password
(<pwdlength>)

Example

at+cpwd=?
+CPWD: ("SC",8),("AB",4),("P2",8),("PS",8)

OK

Reference GSM

07.07

3.5.4.3.8 Calling Line Identification Presentation - +CLIP

+CLIP - Calling Line Identification Presentation

SELINT 0 / 1

AT+CLIP[=[<n>]]

Set command enables/disables the presentation of the CLI (Calling Line
Identity) at the TE. This command refers to the GSM supplementary service
CLIP (Calling Line Identification Presentation) that enables a called
subscriber to get the CLI of the calling party when receiving a mobile
terminated call.

Parameters:
<n>
0 - disables CLI indication (factory default)
1 - enables CLI indication

If enabled the device reports after each RING the response:

+CLIP: <number>,<type>,””,128,<alpha>,<CLI_validity>

where:
<number> - string type phone number of format specified by <type>
<type>
- type of address octet in integer format
128 - both the type of number and the numbering plan are unknown
129 - unknown type of number and ISDN/Telephony numbering plan
145 - international type of number and ISDN/Telephony numbering plan

(contains the character "+")

<alpha> - string type; alphanumeric representation of <number>

corresponding to the entry found in phonebook; used character
set should be the one selected with command Select TE
character set +CSCS.