4 service reporting control - +cr – Rainbow Electronics GM862-QUAD-PY User Manual

Page 74

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 74 of 434

+CRLP - Radio Link Protocol

SELINT 0 / 1 / 2

Parameters:
<iws>
- IWF window Dimension
1..61 - factory default value is 61

<mws> - MS window Dimension
1..61 - default value is 61

<T1> - acknowledge timer (10 ms units).
39..255 - default value is 78

<N2> - retransmission attempts
1..255 - default value is 6

<ver> - protocol version
0

AT+CRLP?

Read command returns the current value of the RLP protocol parameters.

AT+CRLP=?

Test command returns supported range of values of the RLP protocol
parameters.

Reference GSM

07.07

3.5.4.2.4 Service Reporting Control - +CR

+CR - Service Reporting Control

SELINT 0 / 1 / 2

AT+CR=[<mode>]

Set command controls whether or not intermediate result code +CR is
returned from TA to TE.

Parameter:
<mode>
0 - disables +CR reporting (factory default)
1 - enables +CR reporting: the intermediate result code is transmitted at

the point during connect negotiation at which the TA has determined
which speed and quality of service will be used, before any error control
or data compression reports are transmitted, and before the intermediate
result code CONNECT is transmitted. Its format is:

+CR: <serv>

where:
<serv>
ASYNC - asynchronous transparent
SYNC - synchronous transparent
REL ASYNC - asynchronous non-transparent
REL SYNC - synchronous non-transparent.


Note: this command replaces V.25ter [14] command Modulation Reporting
Control (+MR), which is not appropriate for use with a GSM terminal.

AT+CR?

Read command returns whether or not intermediate result code +CR is

Advertising