Rainbow Electronics GM862-QUAD-PY User Manual

Page 252

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 252 of 434

#WAKE - Wake From Alarm Mode

SELINT 0 / 1

activity is stopped (e.g. alarm tone playing) and an OK result code is
returned.


Note: if parameter is omitted, the command returns the operating status
of the device in the format:

#WAKE: <status>

where:
<status>
0 - normal operating mode
1 - alarm mode or normal operating mode with some alarm activity.


Note: the alarm mode is indicated by status ON of hardware pin CTS and
by status ON of pin DSR, the power saving status is indicated by a CTS -
OFF
and DSR - OFF status; the normal operating status is indicated by
DSR - ON.

Note: during the alarm mode the device will not make any network scan
and will not register to any network and therefore is not able to dial or
receive any call or SM, the only commands that can be issued to the
MODULE in this state are the #WAKE and #SHDN, every other command
must not be issued during this state.

AT#WAKE?

Read command has the same effect as Execution command when
parameter is omitted.


#WAKE - Wake From Alarm Mode

SELINT 2

AT#WAKE=
[<opmode>]

Execution command stops any eventually present alarm activity and, if the
module is in alarm mode, it exits the alarm mode and enters the normal
operating mode
.

Parameter:
<opmode> - operating mode
0 - normal operating mode; the module exits the alarm mode, enters the

normal operating mode, any alarm activity is stopped (e.g. alarm tone
playing) and an OK result code is returned.


Note: the alarm mode is indicated by status ON of hardware pin CTS and
by status ON of pin DSR; the power saving status is indicated by a CTS -
OFF
and DSR - OFF status; the normal operating status is indicated by
DSR - ON.

Note: during the alarm mode the device will not make any network scan
and will not register to any network and therefore is not able to dial or
receive any call or SM, the only commands that can be issued to the
MODULE in this state are the #WAKE and #SHDN, every other command
must not be issued during this state.