Rainbow Electronics GM862-QUAD-PY User Manual
Page 386

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 386 of 434
#CSURVC - Network Survey (Numeric Format)
SELINT 2
0 -
3..6 -
<nco> - network control order
0..2 -
<t3168> - timer 3168
<t3192> - timer 3192
<drxmax> - discontinuous reception max time (in seconds)
<ctrlAck> - packed control ack
<bsCVmax> - blocked sequenc countdown max value
<alpha> - alpha parameter for power control
<pcMeasCh> - type of channel which shall be used for downlink
measurements for power control
0 - BCCH
1 - PDCH
(For non BCCH-Carrier)
<arfcn>,<rxLev>
where:
<arfcn> - decimal number; it is the RF channel
<rxLev> - decimal number; it is the receiption level (in dBm)
The last information from #CSURVC depends on the last #CSURVF
setting:
#CSURVF=0 or #CSURVF=1
The output ends with the string:
Network survey ended
#CSURVF=2
the output ends with the string:
Network survey ended (Carrier: <NoARFCN> BCCh: <NoBCCh>)
where
<NoARFCN> - number of scanned frequencies
<NoBCCH> - number of found BCCh
Example
AT#CSURVC
Network survey started…
48,24,-52,0.00,610,1,33281,3648,0,2,30 48,5,14 19 22 48
82
14,8