5 extended error report - +ceer – Rainbow Electronics GM862-QUAD-PY User Manual

Page 75

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 75 of 434

+CR - Service Reporting Control

SELINT 0 / 1 / 2

enabled, in the format:

+CR: <mode>

AT+CR=?

Test command returns the supported range of values of parameter
<mode>.

Reference GSM

07.07

3.5.4.2.5 Extended Error Report - +CEER

+CEER - Extended Error Report

SELINT 0 / 1

AT+CEER

Execution command returns one or more lines of information text <report>
offering the TA user an extended error report, in the format:

+CEER: <report>

This report regards some error condition that may occur:
• the failure in the last unsuccessful call setup (originating or answering)

• the last call release

• the last unsuccessful GPRS attach or unsuccessful PDP context

activation,

• the last GPRS detach or PDP context deactivation.

Note: if none of the previous conditions has occurred since power up then
“No error” condition is reported

AT+CEER?

Read command reports a information text regarding some error condition
that may occur

AT+CEER=?

Test command returns OK result code.

Reference

GSM 07.07, GSM 04.08


+CEER - Extended Error Report

SELINT 2

AT+CEER

Execution command returns one or more lines of information text <report>
offering the TA user an extended error report, in the format:

+CEER: <report>

This report regards some error condition that may occur:
• the failure in the last unsuccessful call setup (originating or answering)

• the last call release

• the last unsuccessful GPRS attach or unsuccessful PDP context

activation,

• the last GPRS detach or PDP context deactivation.

Note: if none of the previous conditions has occurred since power up then
“Normal, unspecified” condition is reported

Advertising