AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 274 of 434
#MONI - Cell Monitor
SELINT 0 / 1
<cc> - country code
<nc> - network operator code
<n> - progressive number of adjacent cell
<bsic> - base station identification code
<qual> - quality of reception
0..7
<lac> - localization area code
<id> - cell identifier
<arfcn> - assigned radio channel
<dBm> - received signal strength in dBm
<timadv> - timing advance
Note: TA: <timadv> is reported only for the serving cell.
1.
If the last setting done by #MONI is 7, the execution command
produces a table-like formatted output, as follows:
a.
First row reports the identifying name of the ‘columns’
#MONI: Cell BSIC LAC CellId ARFCN Power C1 C2 TA
RxQual PLMN<CR><LF>
b.
Second row reports a complete set of GSM-related
information for the serving cell:
#MONI: S: <bsic> <lac> <id> <arfcn> <dBm> <C1value>
<C2value> <timadv> <qual> <netname><CR><LF>
c. 3
rd
to 8
th
rows report a reduced set of GSM-related
information for the cells in the neighbours:
#MONI: N<n> <bsic> <lac> <id> <arfcn> <dBm> <C1value>
<C2value>[<CR><LF>]
where:
<C1value> - C1 reselection parameter
<C2value> - C2 reselection parameter
other parameters as before
AT#MONI=?
Test command reports the maximum number of cells, in the neighbour of
the serving cell, from which we can extract GSM-related informations, along
with the ordinal number of the current selected cell, in the format:
#MONI: (<MaxCellNo>,<CellSet>)
where:
<MaxCellNo> - maximum number of cells, in the neighbour of the serving
cell, from which we can extract GSM-related informations (for
compatibility with previous versions of code this value is always 5).