AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 226 of 434

+CMGW - Write Message To Memory

SELINT 2

Parameter:
<length> - length in bytes of the PDU to be written.
7..164
<stat> - message status.
0 - new message
1 - read message
2 - stored message not yet sent (default)
3 - stored message already sent

The device responds to the command with the prompt '>' and waits
for the specified number of bytes.

To write the message issue Ctrl-Z char (0x1A hex).
To exit without writing the message issue ESC char (0x1B hex).

If message is successfully written in the memory, then the result is
sent in the format:

+CMGW: <index>

where:
<index> - message location index in the memory <memw>.

If message storing fails for some reason, an error code is reported.

Note: care must be taken to ensure that during the command
execution, no other SIM interacting commands are issued.

M

O

D

E

=
0



#

S

M

S

M

O

D

E

=
0



#

S

M

S

M

O

D

E

=
0



#

S

M

S

M

O

D

E

=
0


(Text Mode)
AT+CMGW[=<da>
[,<toda>
[,<stat>]]]

(Text Mode)

Execution command writes in the <memw> memory storage a new
message.

Parameters:
<da> - destination address, string type represented in the currently

selected character set (see +CSCS).

<toda> - type of destination address.
129 - number in national format
145 - number in international format (contains the "+")
<stat> - message status.
"REC UNREAD" - new received message unread
"REC READ" - received message read
"STO UNSENT" - message stored not yet sent (default)
"STO SENT" - message stored already sent

After command line is terminated with <CR>, the device responds
sending a four character sequence prompt: