1 – carrier off with firm time - s10, 2 escape prompt delay - s12 – Rainbow Electronics GM862-QUAD-PY User Manual

Page 64

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 64 of 434

S7 - Connection Completion Time-Out

SELINT 2

ATS7=[<tout>]

Set command sets the amount of time, in seconds, that the device shall
allow between either answering a call (automatically or by A command) or
completion of signalling of call addressing information to network (dialling),
and establishment of a connection with the remote device.

Parameter:
<tout> - number of seconds
1..255 - factory default value is 60

ATS7?

Read command returns the current value of S7 parameter.

Note: the format of the numbers in output is always 3 digits, left-filled with 0s

Reference V25ter

3.5.3.7.1 – Carrier Off With Firm Time - S10

S10 –Carrier Off With Firm Time

SELINT 0 / 1 / 2

ATS10

Execution command has no effect and is included only for backward
compatibility with landline modems

3.5.3.7.2 Escape Prompt Delay - S12

S12 - Escape Prompt Delay

SELINT 0 / 1

ATS12[=<time>]

Set command sets:

1) the minimum period, before receipt of the first character of the three

escape character sequence, during which no other character has to
be detected in order to accept it as valid first character;

2) the maximum period allowed between receipt of first, or second,

character of the three escape character sequence and receipt of the
next;

3) the minimum period, after receipt of the last character of the three

escape character sequence, during which no other character has to
be detected in order to accept the escape sequence as a valid one.

Parameter:
<time> - expressed in fiftieth of a second
20..255 - factory default value is 50.

Note: after CONNECT result code it is possible to accept the first
character of the three escape character sequence without having to
wait for a minimum period to be passed.

ATS12?

Read command returns the current value of S12 parameter.

ATS12=?

Test command returns the range for <time> without command echo and
parenthesis.

Note

For either Read and Test command the format of the numbers in output is
always 3 digits, left-filled with 0s

Advertising