8 reboot - #reboot, 9 cmux interface enable - #cmuxscr – Rainbow Electronics GM862-QUAD-PY User Manual

Page 417

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 417 of 434

#DSCRIPT - Delete Script

SELINT 0 / 1

sensitive)


Note: if the file <script_name> is not present an error code is reported.

Example

AT#DSCRIPT="Third.py"

OK


#DSCRIPT - Delete Script

SELINT 2

AT#DSCRIPT=
[<script_name>]

Execution command deletes a file from Easy Script® related NVM memory.

Parameter:

<script_name> - name of the file to delete, string type (max 16 chars, case

sensitive)


Note: if the file <script_name> is not present an error code is reported.

Example

AT#DSCRIPT="Third.py"
OK

3.5.7.10.8 Reboot - #REBOOT

#REBOOT - Reboot

SELINT 0 / 1

AT#REBOOT

Execution command reboots immediately the unit.

It can be used to reboot the system after a remote update of the script in
order to have the new one running.

AT#REBOOT?

Read command has the same behavior of Execution command.

Example

AT#REBOOT

…. Module Reboots …

Note

This command does not return result codes.


#REBOOT - Reboot

SELINT 2

AT#REBOOT

Execution command reboots immediately the unit.

It can be used to reboot the system after a remote update of the script in
order to have the new one running.

Example

AT#REBOOT


…. Module Reboots …

Note

This command does not return result codes.

3.5.7.10.9

CMUX Interface Enable - #CMUXSCR

#CMUXSCR - CMUX Interface Enable

SELINT 2

AT#CMUXSCR=

Set command enables/disables the GSM 07.10 multiplexing protocol control

Advertising