Rainbow Electronics GM862-QUAD-PY User Manual
Page 429

AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 429 of 434
#RSEN – Remote SIM Enable
SELINT 2
If the ME support the Easy Script Extension® and
<scriptmode> is 1
<muxch> - MDM interface number in scripts; mandatory if
<mode>=1
1 - MDM interface
2 - MDM2 interface
<beacon> - retransmition timer of SAP Connection Request
0 - only one transmition (default)
1..100 - timer interval in seconds.
<scriptmode> - script mode enable; setting this subparameter has a
meaning only if the ME supports the Easy Script®
Extension
0 - disable script mode (see subparameter <muxch>)
1 - enable script mode (see subparameter <muxch>)
Note: enabling the Remote SIM feature when the SIM is already
inserted causes the module to:
• de-register from the actual network
• de-initialize the current SIM.
Note: issuing the command on a not multiplexed interface (see +CMUX)
cause an ERROR to be raised in all the situations except when:
• the ME supports the Easy Script Extension® and
• <scriptmode> is 1
Note: if the Remote SIM feature has been activated the SAP connection
status is signalled with the following URC:
#RSEN: <conn>
where
<conn> - connection status
0 - disconnected
1 - connected
AT#RSEN?
Read command returns the SAP connection status in the format:
#RSEN: <conn>
where
<conn> - connection status, as before
AT#RSEN=?
Test command reports the range of values for all the parameters.