Rainbow Electronics GM862-QUAD-PY User Manual

Page 429

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 429 of 434

#RSEN – Remote SIM Enable

SELINT 2

If the ME support the Easy Script Extension® and

<scriptmode> is 1

<muxch> - MDM interface number in scripts; mandatory if

<mode>=1

1 - MDM interface
2 - MDM2 interface


<beacon> - retransmition timer of SAP Connection Request
0 - only one transmition (default)
1..100 - timer interval in seconds.
<scriptmode> - script mode enable; setting this subparameter has a

meaning only if the ME supports the Easy Script®
Extension

0 - disable script mode (see subparameter <muxch>)
1 - enable script mode (see subparameter <muxch>)

Note: enabling the Remote SIM feature when the SIM is already
inserted causes the module to:
• de-register from the actual network

• de-initialize the current SIM.

Note: issuing the command on a not multiplexed interface (see +CMUX)
cause an ERROR to be raised in all the situations except when:
• the ME supports the Easy Script Extension® and

<scriptmode> is 1

Note: if the Remote SIM feature has been activated the SAP connection
status is signalled with the following URC:

#RSEN: <conn>
where
<conn> - connection status
0 - disconnected
1 - connected

AT#RSEN?

Read command returns the SAP connection status in the format:

#RSEN: <conn>
where
<conn> - connection status, as before

AT#RSEN=?

Test command reports the range of values for all the parameters.