Rainbow Electronics GM862-QUAD-PY User Manual

Page 159

Advertising
background image




AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 159 of 434

+CGQMIN - Quality Of Service Profile (Minimum Acceptable)

SELINT 0 / 1

OK

Reference

GSM 07.07; GSM 03.60


+CGQMIN - Quality Of Service Profile (Minimum Acceptable)

SELINT 2

AT+CGQMIN=
[<cid>
[,<precedence>
[,<delay>
[,<reliability>
[,<peak>
[,<mean>]]]]]]

Set command allows to specify a minimum acceptable profile which is
checked by the terminal against the negotiated profile returned in the
Activate PDP Context Accept message.

Parameters:
<cid> - PDP context identification (see +CGDCONT command).
<precedence> - precedence class
<delay> - delay class
<reliability> - reliability class
<peak> - peak throughput class
<mean> - mean throughput class

If a value is omitted for a particular class then this class is not checked.

Note: a special form of the Set command, +CGQMIN=<cid> causes the
requested profile for context number <cid> to become undefined.

AT+CGQMIN?

Read command returns the current settings for each defined context in the
format:

+CGQMIN: <cid>,<precedence>,<delay>,<reliability>,<peak>,
<mean>[<CR><LF>+CGQMIN: <cid>,<precedence>,
<delay>,<reliability>,<peak>,<mean>[…]]


If no PDP context has been defined, it has no effect and OK result code is
returned.

AT+CGQMIN=?

Test command returns as a compound value the type of the current PDP
context and the supported values for the subparameters in the format:

+CGQMIN: <PDP_Type>,(list of supported <precedence>s),
(list of supported <delay>s),(list of supported <reliability>s),
(list of supported <peak>s),(list of supported <mean>s)

Note: only the “IP” PDP_Type is currently supported.

Example

AT+CGQMIN=1,0,0,3,0,0
OK
AT+CGQMIN?

+CGQMIN: 1,0,0,5,0,0

OK

AT+CGQMIN=?
+CGQMIN: “IP”,(0-3),(0-4),(0-5),(0-9),(0-18,31)

OK

Advertising