AT Commands Reference Guide

80000ST10025a Rev. 5 - 09/07/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 136 of 434

+CALA - Alarm Management

SELINT 2

0 - The only value supported is 0.
<type> - alarm behaviour type
0 - reserved for other equipment use.
1 - the MODULE simply wakes up fully operative as if the ON/OFF button

had been pressed. If the device is already ON at the alarm time, then it
does nothing (default).

2 - the MODULE wakes up in "alarm mode" if at the alarm time it was off,

otherwise it remains fully operative. In both cases the MODULE issues
an unsolicited code every 3s:

+CALA: <text>

where <text> is the +CALA optional parameter previously set.

The device keeps on sending the unsolicited code every 3s until a
#WAKE or #SHDN command is received or a 90 seconds timer expires.
If the device is in "alarm mode" and it does not receive the #WAKE
command within 90s then it shuts down.

3 - the MODULE wakes up in "alarm mode" if at the alarm time it was off,

otherwise it remains fully operative. In both cases the MODULE starts
playing the alarm tone on the selected path for the ringer (see command
#SRP)
The device keeps on playing the alarm tone until a #WAKE or #SHDN
command is received or a 90 s time-out occurs. If the device is in "alarm
mode" and it does not receive the #WAKE command within 90s then it
shuts down.

4 - the MODULE wakes up in "alarm mode" if at the alarm time it was off,

otherwise it remains fully operative. In both cases the MODULE brings
the pin GPIO6 high, provided its <direction> has been set to alarm
output, and keeps it in this state until a #WAKE or #SHDN command is
received or a 90 seconds timer expires. If the device is in "alarm mode"
and it does not receive the #WAKE command within 90s then it shuts
down.

5 - the MODULE will make both the actions as for type=2 and <type>=3.
6 - the MODULE will make both the actions as for type=2 and <type>=4.
7 - the MODULE will make both the actions as for type=3 and <type>=4.
8 - the MODULE wakes up in "alarm mode" if at the alarm time it was off,

otherwise it remains fully operative. In both cases the MODULE sets
High the RI output pin. The RI output pin remains High until next
#WAKE issue or until a 90s timer expires. If the device is in "alarm
mode" and it does not receive the #WAKE command within 90s. After
that it shuts down.

<text> - unsolicited alarm code text string. It has meaning only if <type> is

equal to 2 or 5 or 6.

<recurr> - string type value indicating day of week for the alarm in one of

the following formats:

“<1..7>[,<1..7>[, … ]]” - it sets a recurrent alarm for one or more days in