Verify – Yaskawa iQpump Controller Programming Manual User Manual

Page 140

Advertising
background image

140

YASKAWA

TM.iQp.07 iQpump Controller Programming Manual

A successful COPY of the parameter values will display:

An error may occur while writing the parameter values to the drive. If an error is displayed, press any key to cancel the error display and
return to parameter o3-01. Error displays and their meanings are covered in Chapter 6: Diagnostics and Troubleshooting of the iQpump
User Manual (TM.iQp.06).

It is possible to compare the parameter values stored in the digital operator with the parameter values currently in the iQpump drive by
using the VERIFY function. This VERIFY function should not be confused with the “-VERIFY-” that is displayed on the digital operator
when viewing the “Modified Constants” menu. To VERIFY the parameter values in the iQpump drive as compared with those stored in
the digital operator, set o3-01 = “3: OP

↔INV VERIFY”. During the comparing of the parameter values into the iQpump drive the digital

operator will display:

A successful VERIFY of the parameter values will display:

If all the parameter values stored in the digital operator do not match those programmed in the drive, the digital operator displays the
following:

The digital operator will not display which parameters did not match, only that the verification found discrepancies in some parameter
values.

Note: In order to properly use the COPY or VERIFY functions, the following iQpump drive specifications must be identical

between the iQpump drive that the parameters were read from and the iQpump drive that the parameters are to be
written to:

• Model Number (e.g. CIMR-P7U2015-107)
• Software Number (e.g. 30030 also known as FLASH ID)

Yaskawa offers DriveWizard™ software that can also READ, COPY, and VERIFY iQpump drive parameter values. DriveWizard™ lists
all discrepancies between the iQpump drive and a pre-saved parameter file when verifying is performed.

To use DriveWizard first select o2-15 = “0: Disabled” and select o2-06 = “0: Disabled” then remove the digital operator / keypad and
attach the DriveWizard cable in its place.

-ADV-

COPY

COPY COMPLETE

-ADV-

VERIFY

DATA VERIFYING

-ADV-

VERIFY

VERIFY COMPLETE

-ADV-

VYE

VERIFY ERROR

Advertising