H2 Digital Outputs

Terminal Function Selections

Setting Range:

0 ~ 57

Factory Defaults: H2-01 = “40: Pump 2 Control”

H2-02 = “41: Pump 3 Control”

The iQpump drive has two multi-function outputs. By programming parameters H2-01 and H2-02, the user can assign specific functions
to each output. Below is a table with a complete list of all of the digital output functions. Because the iQpump drive is a dedicated pump
controller, the digital outputs described in this section only relate to the pump specific functions. Following the table is a more detailed
description of each of the pump related functions.

Table 29 Digital Output Functions

Table 30 Parameters

<0034>

Parameter No.

Parameter Name

H2-01

Terminal M1-M2 Function Selection

H2-02

Terminal M3-M4 Function Selection

Parameter setting

Function

Parameter setting

Function

0

During Run1

3B

Run from Serial Com

1

Zero Speed

3D

Cooling Fan Err

2

FREF / FOUT Agree 1

40

Pump 2 Control

3

FREF / Set Agree 1

41

Pump 3 Control

4

Frequency Detect 1

42

Pump Fault

5

Frequency Detect 2

43

Mot 2 Alternate

6

Drive Ready

44

Sleep Active

7

DC Bus Undervoltage

45

Start Lvl Delay

8

Baseblock 1

46

Thrust Bearing

9

Option Reference

47

Pre-charge

A

Remote Operation

48

High Feedback

B

Torque Detect 1 N.O.

49

Low Feedback

C

Loss of Reference

4A

Transducer Loss

E

Fault

4B

Setpoint Not Met

F

Terminal Not Used

4C

Loss of Prime

10

Minor Fault

4D

Thermostat Fault

11

Reset Cmd Active

4E

Low Flow

12

Timer Output

4F

Accum Level

17

Torque Detect 1 N.C.

50

Utility Delay

1A

Reverse Direction

51

Run / Stop-Stop

1E

Restart Enabled

52

Run / Stop-Finish

1F

Overload (OL1)

53

Anti-Jam / De-Scale

20

OH Pre-alarm

54

During Run 2

38

Drive Enable

55

Lube Pump

39

Drive Waiting

56

High Flow

3A

Frequency Reduced, OH

57

Low Water Level

Parameter

No.

Addr.

Hex

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Menu

Location

H2-01

40B

Terminal M1-M2 Function
Selection
Terminal M1-M2 Sel

Selects the functionality of the M1-M2 digital output contacts.

0 ~ 57

40

Programming

H2-02

40C

Terminal M3-M4 Function
Selection
Terminal M3-M4 Sel

Selects the functionality of the M3-M4 digital output contacts.

0 ~ 57

40

Programming