INFICON HAPSITE Smart Plus Chemical Identification System User Manual
Page 492
15 - 18
IP
N 07
4-
47
2-
P1
C
HAPSITE Smart Plus Operating Manual
3
Double-clicking on the Service Module icon will open the Service Module tab
in the HAPSITE Properties window, as shown in
Figure 15-24
.
Figure 15-24 Service Module Tab Selected in HAPSITE Properties Window
4
In the Service Module tab shown above, select the Detach button. A message
will appear looking for confirmation to detach the HAPSITE, as shown in
Figure
15-25
. Select Yes. A Detaching Service Module message is displayed. See
Figure 15-25 Detach HAPSITE Confirm Window
Figure 15-26 Detach In Process
5
The HAPSITE Vacuum Interconnect valve will close shortly after selecting
DETACH.
NOTE: The detach procedure typically takes about 3 to 5 minutes to complete.
NOTE: After pressing the Detach button and selecting Yes on the confirm
window, the HAPSITE Properties window can be closed.