Chapter 4

Inspection Configuration

4–20

Here is a brief description of each field in the

Results

display setup panel:

Title –– This field enables the user to select an appropriate name or “title”
for the results display panel that corresponds to the currently selected
toolset. By default, the initial title is “

Results

” plus the position number

of the toolset in the

Configuration Editor

panel. Thus, the default titles

of the results panels for toolsets #1, #3, and #6 would be

Results 1

,

Results 3

, and

Results 6

, respectively.

Panel Position –– This parameter reflects the X– and Y–axis coordinates
of the upper–left and lower–right corners, respectively, of the results
display panel for currently selected toolset in the

Configuration Editor

panel (as illustrated in Figure 4.15 on page 4–22). When you pick the

Panel Position

field, the results display panel for the selected toolset

appears on the screen, and is is accessible for resizing and repositioning
on the screen. (The image and results display panels for other toolsets are
also available at this time; however, they may appear on the screen as
icons.)

Start Iconized ? –– This parameter determines whether online operations
begin with the results display panel on the screen (“

No

”), or with an icon

representing the panel appearing at the right side of the screen (“

Yes

”).

The default selection is “

No

.”

Setting Up Inspection Tools

NOTE: This section covers only the general configuration procedures. For
detailed information about the inspection tool types and tool operations, refer
to Chapter 7, Inspection Tools.

Assuming that the

Configuration Editor

panel contains the “

Toolset 1

,”

Toolset 2

,” and “

Toolset 3

” inspections (as shown in Figure 4.7 on page

4–9), continue the configuration procedure with the following steps:

1. If you want to change the archive name “

EE:FrontLabel.ts1

” to some

other name, pick the field containing the

EE:FrontLabel.ts1

name.

When you do, the

File Select

panel appears on the screen, as shown in

Figure 4.14 (page 4–21).

Pick the

button to access the keyboard. Enter the new archive

name, then pick the

key to save the name, exit the keyboard, and

return to the

File Select

panel. Pick the

button to exit back to the

Configuration Editor

panel.

2. The small arrow (

→) alongside the toolset number indicates which

toolset is currently selected. Pick “1” to select the first toolset.

Advertising