Chapter 6

Reference Tools

6–78

This section discusses the expanded inspection results that are available to a
math tool formula from a build reference tool. As Figure 6.67 shows, the
expanded inspection results for a build reference tool appear in one list.

Figure 6.67 Expanded Results Lists For Build Reference Tools in Math Formulas

Execute
Pass
Warn
Fail
Total
Faults
X
Y
Theta

nX

nY

nTheta
Xc
Yc

Here is a brief definition and explanation of each of the expanded result
types listed in Figure 6.67 (page 6–78).

Execute –– This returns a

1.000

when the tool has executed its inspection

task, and

0.000

for all other conditions.

Pass –– This returns a

1.000

when the tool has passed its inspection task,

and

0.000

for all other conditions.

Warn –– For reference tools,

Warn

always returns

0.000

.

Fail –– This returns a “error code” when the tool is in a fail condition and

0.000

for all other conditions. The error code identifies a specific reason

for the failure; for example, error code

1049.000

identifies “Could not

access result” as the cause of the inspection failure. The complete list of
error codes and fail conditions appears in Appendix A of this manual.

Total –– This returns the total number of inspections performed.

Faults –– This returns the total number of faults detected.

X –– This returns the current value of the X result from the

X Formula

in

the build reference tool. (It is

0.000

if the

X Mode

is

Enabled

, but has

no usable

X Formula

, or it is

Disabled

.)

Y –– This returns the current value of the Y result from the

Y Formula

in

the build reference tool. (It is

0.000

if the

Y Mode

is

Enabled

, but has

no usable

Y Formula

, or it is

Disabled

.)

Build Reference Tool
Inspection Results and
Math Tool Formulas

Advertising